CONTROLLER SKID ASSEMBLIES
Model Number PDF Description
SSCPRF3E-A7Y-2P2S SKID ASSY 001
SS-O Series controller with conductivity, pH and ORP parameters. Inhibitor and Biocide each via pump, One solenoid for bleed-off, One solenoid for erosion feeder. Mounted on skid with ERF12KG Erosion Feeder and ONGA-413 circulation pump
SSCPRF3E-A7Y-3P1S SKID ASSY 001 SS-O Series controller with conductivity, pH and ORP parameters. ORP, Inhibitor and Biocide each via pump. One solenoid for bleed-off. Mounted on skid with ONGA-413 circulation pump
SSCPRF3E-A7Y-2P2S ENCL SKID ASSY 001
SS-O Series controller with conductivity, pH and ORP parameters. Inhibitor and Biocide each via pump, One solenoid for bleed-off, One solenoid for erosion feeder. Mounted on skid with ERF12KG Erosion Feeder and ONGA-413 circulation pump. Controller and pumps mounted in enclosure, manifold outside
SSCPRF3E-A7Y-3P1S ENCL SKID ASSY 001
SS-O Series controller with conductivity, pH and ORP parameters. ORP, Inhibitor and Biocide each via pump. One solenoid for bleed-off. Mounted on skid with ONGA-413 circulation pump. Controller and pumps mounted in enclosure, manifold outside
CORROSION COUPON RACK
Model Number PDF Description
COR-RACK-2C 2-coupon corrosion rack with quick-release coupon holders. Tool free
COR-RACK-4C 4-coupon corrosion rack with quick-release coupon holders. Tool free

Installation Drawings

TOWER
Model Number PDF Description
SSCF3-A7Y-3P1S_CIRC_PUMP_INSTALL 001
SS-T Dual Biocide controller with conductivity parameter only. Inhibitor, Biocide A and Biocide B each via pump. One solenoid for bleed-off. System installed by drawing flow from the tower using an ONGA-413 circulation pump
SSCF3-A7Y-3P1S_DIRECT_INSTALL 001
SS-T Dual Biocide controller with conductivity parameter only. Inhibitor, Biocide A and Biocide B each via pump. One solenoid for bleed-off. System installed by drawing flow directly from tower after the main tower circulation pump
SSCPRF3E-A7Y-3P1S_CIRC_PUMP_INSTALL 001
SS-O Series controller with conductivity, pH and ORP parameters. ORP, Inhibitor and Biocide each via pump. One solenoid for bleed-off. System installed by drawing flow from the tower using an ONGA-413 circulation pump
SSCPRF3E-A7Y-3P1S_DIRECT_INSTALL 001
SS-O Series controller with conductivity, pH and ORP parameters. ORP, Inhibitor and Biocide each via pump. One solenoid for bleed-off. System installed by drawing flow directly from tower after the main tower circulation pump
SSCPRF3E-A7Y-2P2S_CIRC_PUMP_INSTALL 001 SS-O Series controller with conductivity, pH and ORP parameters. Inhibitor and Biocide each via pump, One solenoid for bleed-off, One solenoid for ERF12KG Erosion Feeder. System installed by drawing flow from the tower using an ONGA-413 circulation pump
SSCPRF3E-A7Y-2P2S_DIRECT_INSTALL 001 SS-O Series controller with conductivity, pH and ORP parameters. Inhibitor and Biocide each via pump, One solenoid for bleed-off, One solenoid for ERF12KG Erosion Feeder. System installed by drawing flow directly from tower after the main tower circulation pump
SSCPRF3E-A7Y-3P1S CIRC PUMP SKID INSTALL 001 SS-O Series controller with conductivity, pH and ORP parameters. ORP, Inhibitor and Biocide each via pump. One solenoid for bleed-off. Mounted on skid with ONGA-413 circulation pump. System installed by drawing flow from the tower using an ONGA-413 circulation pump
SSCPRF3E-A7Y-2P2S CIRC PUMP SKID INSTALL 001 SS-O Series controller with conductivity, pH and ORP parameters. ORP, Inhibitor and Biocide each via pump. One solenoid for bleed-off. Mounted on skid with ONGA-413 circulation pump
BOILER
Model Number PDF Description





Member of WIOA Member of AWA Member of  the Pump Industry Australia